| Frequency Range |
R&S® ESRP3 |
AC coupled: 10 MHz to 3.6 GHz
DC coupled: 9 kHz to 3.6 GHz |
|
R&S® ESRP7 |
AC coupled: 10 MHz to 7 GHz
DC coupled: 9 kHz to 7 GHz |
|
With R&S® ESRP-B29 option |
DC coupled: 10 Hz to max. frequency |
| Frequency Resolution |
Receiver mode |
0.1 Hz |
|
Analyzer mode |
0.01 Hz |
| Number of Sweep / Trace Points |
Spectrum analyzer |
101 to 32 001 |
|
EMI measurement |
101 to 200 001 |
| Preselection Filters |
With R&S® ESRP-B2 option |
16 filters |
| RF Preamplifier |
R&S® ESRP-B2 / FSV-B22 options |
20 dB nominal gain |
| Operating Modes |
EMI test receiver and spectrum analyzer |
| Receiver Scan |
Up to 10 subranges
Normal scan and time domain scan |
| Number of Trace Points |
Up to 4 000 000 |
| Resolution Bandwidth |
10 Hz to 10 MHz in 1/2/3/5 sequence
20 MHz, 28 MHz and 40 MHz additionally in zero span |
| EMI Bandwidths |
Standard: 200 Hz, 9 kHz, 120 kHz, 1 MHz
With R&S® ESRP-B29 option: 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz additionally |
| Video Bandwidth |
1 Hz to 10 MHz in 1/2/3/5 sequence; 20 MHz, 28 MHz and 40 MHz |
| Detectors |
Max. peak, min. peak, RMS, average, quasi-peak, CISPR average and RMS average |
| Maximum Input Level |
AC coupled: 50 V
DC coupled: 0 V
CW RF power: up to 30 dBm with RF attenuation ≥ 10 dB |
| RF Input |
50 Ω, N female |
| Input Attenuator |
0 dB to +70 dB, in 10 dB steps |
| Trigger Source |
Analyzer mode: free run, video, external, IF power
Receiver mode: free run, video, external |
| Remote Control |
LAN, USB and IEC/IEEE bus control interface |
| Display |
8.4" LC TFT color display, 800 × 600 pixel |
| Data Storage |
Internal SSD ≥ 120 GB; external USB 2.0 memory support |
| Operating Temperature |
+5°C to +40°C |
| Power Supply |
100 V to 240 V, 50 Hz to 400 Hz |
| Power Consumption |
100 W, max. 180 W with all options |
| Dimensions (W×H×D) |
412 × 197 × 417 mm |
| Weight |
9.5 kg without options |